Wireless schock and tilt detector
The detector is a component of the JABLOTRON system. It has two selectable operation modes. The mode for the detection of shocks / vibrations of doors, windows etc. can be used to indicate attempts to breach these by force. The tilt detection mode can be used to indicate unwanted tampering with the object to which the detector is firmly fixed. This may be used for safes, artworks etc.). The detector should be installed by a trained technician with a valid certificate issued by an authorized distributor.
Installation
- Open the detector by pushing cover latch.
- Screw on the rear housing part to the desired place.
- Insert the battery to the battery holder (3).
- Set up the function of detector by DIP switch (5) – shock (2 ON); tilt (2 OFF) and reaction – delayed (1 OFF); confirmed (1 ON).
- Adjust the detector sensitivity with the trimmer (2), close the detector and secure by locking screw.
1 – serial number; 2 – swivel trimmer for adjusting sensitivity; 3 – battery holder; 4 – tamper contact; 5 – configuration switch;
Enrolment to the system and settings
Depending on the type of control panel, use the recommended software or application, see the control panel manual.
Technical specification
Power | lithium battery type CR123A (3.0 V/1.4 Ah) Please note: Battery is not included |
---|---|
Tilt detection (according to the settings) | 10 °–45 ° |
Typical battery lifetime | approx. 2 years (with max. 20 activations a day) |
Low battery voltage | <2.4 V |
Communication band | 868.1 MHz, Jablotron protocol |
Quiescent current consumption | 24 μA |
Maximal current consumption | 50 mA |
Maximum radio-frequency power (ERP) | <25 mW |
Communication range | approx. 300 m (open area) |
Dimensions | 75 x 31 x 26 mm |
Weight (without battery) | 22.5 g |
Classification | security grade2/environmental class II (according to EN 50131-1) |
Environment | indoor general |
Operating tamperature range | -10 °C to +40 °C |
Average operating humidity | 75% RH, non-condensing |
Certification body | Trezor Test s.r.o. (no. 3025) |
According to | EN 50131-1, -2-8, -5-3, ETSI EN 300 220-2, EN 50130-4, EN IEC 63000, EN 55032, EN IEC 62368-1 |
Can be operated according to | ERC REC 70-03 |
Recommanded screw | 2 x ø 3.5 x 40 mm (countersunk head) |
JABLOTRON a.s. hereby declares that the JA-182SH is in a compliance with the relevant Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – Section Downloads. | ||
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point. |
JA-182SH | MLB56109 (13.12.2024) |
---|