JA-180PB


If you want to save to PDF, please select
‘Save as PDF’ when the print dialog opens.

Combined PIR and Glass break Detector

switch to the manual for the JABLOTRON 100+ system

The product is a component of JABLOTRON alarm system. It consists of two independent detectors which occupy two separate enrolment addresses in the control panel. The motion detector uses a PIR sensor. The glass-break detector uses the analysis of air pressure variations combined with the characteristic sound of glass breaking. The product is designed for internal use in buildings. The battery-powered detector communicates via Jablotron radio protocol. The product should be installed by a trained technician with a valid certificate issued by an authorized distributor of Jablotron.

Installation

  1. Open the detector cover by pressing the tab and disconnect the cable to the GBS module located in the front cover.
  2. Remove the internal PIR module held by an internal tab.
  3. Punch screw holes through the rear plastic cover. At least one screw should penetrate the tamper-sensitive section.
  4. Screw the rear cover to the wall, about 2 meters above the floor (vertically, with the tab down).
  5. Return the PIR module to its original place. Insert batteries to both modules, connect cable of GBS module to the PCB of the PIR detector and follow assignment instruction below.
  6. Close the detector cover and secure the tab by the supplied locking screw to comply EN 50131-2-2.
Figure 1: PIR movement detector, Figure 2: Glass-break detector
1 – LED; 2 – detection sensor; 3 – tamper contact; 4 – detection (normal / high); 5 – reaction (delay / instant); 6 – input; 7 – tab; 8 – cover tab; 9 – LED indication (GBS / PIR); 10 – reaction (instant / delay); 11 – GBS sensitivity;

Assignment to the system and settings

According to the type of control panel use recommended software or application – see control panel manual.

Technical specifications

Power of PIR sensorLithium battery type CR14500 (AA) 3.6 V / 2.45 Ah
Power of GBS sensorLithium battery type CR14250 (1/2AA) 3.6 V / 1.2 Ah
Please note: Batteries are not included
Typical battery lifetimeapprox. 3 years (PIR sensor sleep time 5 min.)
Quiescent current consumption38 μA
Maximal current consumption40 mA
Low battery voltage2.6 V
Maximum radiofrequency power (ERP)< 25 mW
Communication frequency868.1 MHz, Jablotron protocol
Communication rangeapprox. 300 m (open area)
Recommended installation height2–2.5 m above floor level
PIR detection angle / detection range120° / 12 m (with basic lens)
GBS detection range9 m (glass min. 60 x 60 cm)
Operational environmentII. Indoor general (EN 50131-1)
Detection typeacoustic
Operational temperature range-10 °C to +40 °C
Average operating humidity75% RH non-condensing
Dimensions10 x 60 x 55 mm
Weight120 g
ClassificationGrade 2 (EN 50131-1)
Complies withEN 50131-1, EN 50131-2-2, EN 50131-6, EN 50131-2-7-1, EN 50131-5-3, ETSI EN 300 220-1,-2, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63 000
Can be operated according toERC REC 70-03
Recommended screw2 x ø 3.5 x 40 mm (countersunk head)



JABLOTRON a. s. hereby declares that the JA-180PB is in a compliance with the relevant Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – Section Downloads.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.

JA-180PBMHP500406
(09.04.2025)