The product is component of the JABLOTRON system. It is designed to remotely control a security system, various appliances (using PG programmable outputs) or to trigger panic alarms and more. The remote is equipped with optical and acoustic indication. It checks its battery status and indicates when the battery is nearly discharged. The remote communicates via the Jablotron wireless protocol and is powered by a single power cell. There must be a JA-11xR radio module installed in the control panel for the ability to work with a control panel. The device should be installed by a trained technician with a valid certificate issued by an authorised distributor.

Operation with a multipurpose relay (MPR)

The remote control can also be enroled to a multipurpose relay of the AC-16x series, to control a relay according to the chosen mode. Each button should be enroled to the MPR with a different mode. Even one remote can be enroled to multiple MPRs for example with a different function. When you enrol a keyfob to the control panel and also to an MPR within its RF range, don´t select the same buttons. To enrol a keyfob to an MPR, follow the installation manual of the MPR.

If the remote control is out of the RF range of the radio module or MPR, it doesn´t indicate status change or signal loss.

Locking the keyfob

The remote control buttons can be locked (blocked) against accidental pressing. Locking is disabled by default, pressing any button triggers its function immediately. If the buttons are locked, a control panel command is sent when a button is pressed 2x quickly (2x per 1 s) it is also valid for the panic function.

Caution: When a reaction for pressing buttons (A+B) simultaneously is set (for example a panic alarm or garage door control), it is necessary to mind that the action is performed first.

The lock can be activated by simultaneously pressing and holding the pair of buttons (A+B) until the yellow LED (1) starts flashing, usually in 3 s. When the yellow LED (1) is flashing release button (B) and press it again. Activation of the lock function is performed and confirmed by double flashes of the yellow LED and a double beep. After this confirmation release all buttons.

The lock is deactivated by repeating the procedure above. Deactivation of locking is confirmed by one flash of the yellow LED and one beep.

Acoustic indication

Acoustic indication can be completely disabled. The default is enabled. When any button is pressed it is followed by a short acoustic signal according to the table 1.

Caution: When a reaction for pressing buttons (A+B) simultaneously is set (for example a panic alarm or garage door control), it is necessary to mind that the action is performed first.

The acoustic indication can be disabled by simultaneous pressing and holding the pair of buttons (A+B) until the yellow LED (1) starts flashing briefly for the second time, usually in 6 s. When the yellow LED (1) flashes a second time release the button (B) and press it again. The acoustic indication is then disabled and confirmed by flashes of the yellow LED and a one beep. After this confirmation release all buttons.

The acoustic indication can be enabled by repeating the procedure above. Activation is confirmed by a double flash of the yellow LED and a double beep.

Figure 1: Description of the external parts of the device
1 – LED indication; A, B – buttons to which functions can be enroled;
ActionIndication
The press of a button is indicated by an acoustic signal (if set) followed by a LED flash of corresponding colour. The mentioned indication statuses are valid for the remote’s default setting.
UnsettingControl function with confirmation by LED1x flash of green LED and 2x short acoustic signals
Setting1x flash of red LED and 1x short acoustic signal
Partial setting1x flash of yellow LED and 1x short acoustic signal
Table 1: Remote control indication

Enrolment to the system and settings

According to the type of control panel use recommended software or application – see control panel manual.

Technical specifications

Power1x lithium battery type CR 2032 (3.0 V/0.2 Ah)
(Power supply C type according to EN 50131-6)
Quiescent current consumption1.1 μA
Maximal current consumption33 mA
Low battery voltage≤2.2 V
Typical battery lifetimeapprox. 2 years (10 activations/day)
Communication frequency868.1 MHz, JABLOTRON protocol
Maximum radiofrequency power (ERP)<25 mW
RF rangeapprox. 300 m (line of sight)
Dimensions63 x 36 x 15 mm
Weight without the battery32 g
ClassificationSecurity grade 2/Environmental class II (According to EN 50131-1)
EnvironmentalIndoor general
Operational temperature range-10 °C to +40 °C
Average humidity75% RH, non-condensing
Number of unique production codes>1 Million
Certification bodyTrezor Test s.r.o. (no. 3025)
Additionaly in compliance withETSI EN 300 220-1,-2, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000, EN 50131-1, EN 50131-3, EN 50131-5-3, EN 50131-6, EN IEC 62311
Can be operated according toERC REC 70-03
Compatible withFW of the JA-11xR module LR6x613+, FW of the control panel LJ(MD)60416+



JABLOTRON a.s. hereby declares that the product JA-152J MS II is in a compliance with the relevant Union harmonisation legislation: Directives No: 2014/30/EU, 2014/35/EU, 2014/53/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – Section Downloads.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.