The JA-151TH is a component of the JABLOTRON system. It serves for temperature measurement and forwarding measured data to MyJABLOTRON. MyJABLOTRON analyses and stores measured data for further use for instance activating a selected PG output, the SMS reporting of exceeding temperature limits or to create graphs of measured temperatures. This product should be installed by a trained technician with a valid certificate issued by an authorised distributor of Jablotron.

Select the installation place according to the temperature measuring requirements. It is not recommended to install the detector near heat sources affecting measuring (heaters, electric fans, air conditioning outlets, fireplace inserts, etc.). The detector can also be installed in an outdoor environment, but it has to be placed into a suitable box with a minimum of IP65 housing, the JA-192PL-A for example.

Installation

  1. Open the cover by pushing the tab (1).
  2. Screw the rear plastic base to the required place using screws.
  3. Insert the battery into the detector and close the detector cover.
Pic. 1: Description of external and internal parts of the product
1 – cover tab; 2 – LED indication; 3 – production code; 4 – activation button; 5 – battery;

Assignment to the system and settings

Depending on the type of control panel, use the recommended software or application, see the manual of the control panel.

Technical specifications

Power1 x Lithium battery type CR2032 (3.0 V/0.2 Ah)
Please note: Battery is not included
Quiescent current consumption5 µA
Maximal current consumption34 mA
Typical battery lifetimeabout 2 years
Low battery voltage<2.3 V
Communication band868.1 MHz, JABLOTRON protocol
RF rangeup to 200 m (open area)
Dimensions55 x 27 x 16 mm
Weight13 g
Temperature measurement range-20 to +70 °C
Operational temperature-20 to +70 °C
Temperature measurement range accuracy±0.5 °C
Average operating humidity75% RH, non-condensation
Can be operated according toERC REC 70 03
Also complies withETSI EN 300 220-1,-2, EN-62368-1, EN 50130-4, EN 55032, EN IEC 63000
Recommended screw2 x ø 3,5 x 40 mm (countersunk head)



JABLOTRON a.s. hereby declares that the JA-151TH is in a compliance with the relevant Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – Section Downloads.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.

JA-151THMNG54310
(15.11.2024)