Bus dual PIR and MW motion detector
This product is a bus component of the JABLOTRON system. It is designed to detect human body movement inside buildings. A high immunity to false alarms is reached thanks to the combination of PIR and microwave (MW) detection. The immunity to false alarms can be set at two levels, PIR and MW. The detector operates with a pulse reaction (only indicates its activation) and takes up a single position in the system. This detector is intended to be installed by a trained technician with a valid certificate issued by an authorised distributor.
Installation
Always switch the power off before connecting the detector to the system bus. |
- Open the detector cover by pushing the tab (13). Avoid touching the PIR sensor inside (7) – you could damage it.
- Take out the PCB – It is held in place by tabs (9) at the lower part of the cover.
- Punch through the holes (1) for the screws and the cable in the plastic base. The recommended detector installation height is 2.5 m above the floor. In order to fully take advantage of device removal tamper detection, it is necessary to utilize the screw hole surrounded by perforation.
- Insert the bus cable through the holes (1) and attach the plastic base to the wall using screws (vertically, with the cover tab facing downwards).
- Put the PCB back and connect the bus cable to the terminals (2).
- Bus cables must not reach beyond the divider (14) that protects the MW sensor. Cables reaching into the area beyond the divider can negatively impact the functionality of the MW sensor.
- Proceed according to the control panel installation manual. The control panel must be in service mode.
- Then close the detector cover. In order to be fully compliant with regulations, it is necessary to fix the cover in place with the use of a fixing screw (12).
1 – wiring knockout holes; 2 – digital bus terminals; 3 – MW sensor; 4 – production code; 5 – LED; 6 – The JA-191PL external tamper connector; 7 – PIR sensor; 8 – tamper contact; 9 – PCB tab; 10 – light indicator; 11 – PIR lens; 12 – fixing screw hole; 13 – cover tab; 14 – MW sensor protective divider;
Assignment to the system and settings
Depending on the type of control panel, use the recommended software or application, see the manual of the control panel.
Technical specifications
Power supply | from the control panel bus 12 V DC (9…15 V) |
---|---|
Quiescent current consumption | 5 mA |
Maximal current consumption | 16 mA |
Recommended installation height | 2.5 m above floor level |
Detection angle/PIR coverage | 90 °/12 m |
Detection angle/MW coverage | 80 °/12 m |
MW Frequency | 24.125 GHz |
Maximum MW radio-frequency power (ERP) | 30 mW |
Dimensions | 150 x 63 x 40 mm |
Weight | 120 g |
Classification | Security grade 2/Environmental class II (According to EN 50131-1) |
Environment | Indoor general |
Operating temperature range | -10 °C to +40 °C |
Average operational humidity | 75% RH, w/o condensation |
Certification body | Trezor Test s.r.o. (no. 3025) |
In compliance with | ETSI EN 300 440, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000, EN 50131-1, EN 50131-2-4, T 031 |
Operating conditions according to | general authorization ERC REC 70-03 |
Recommended screw | 2 x ø 3.5 x 40 mm (countersunk head) |
JABLOTRON ALARMS a.s. hereby declares that the JA-122PW, JA-122PW-GR, JA-122PW-AN is in compliance with the relevant European Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU, when used as intended. The original of the conformity assessment can be found at www.jablotron.com – the Downloads section. | ||
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point. |
JA-122PW | MON52605 (02.08.2024) |
---|