JA-122PB


If you want to save to PDF, please select
‘Save as PDF’ when the print dialog opens.

Bus combined PIR motion and glass break detector

type: 1PIRGBS2201OQ

switch to the manual for the JABLOTRON 100+ system

The detector is a component of the JABLOTRON system. It serves for the detection of human movement in building interiors and for the detection of breaking glass windows. This detector combines two sensors (the detector occupies two positions in the system) in one housing. The detector uses a PIR sensor for human movement detection. Breaking glass is detected by a GBS sensor, which analyses air pressure changes and sounds to detect the breaking of a glass window. The detector should be installed by a trained technician with a valid certificate issued by an authorized distributor.

Installation

When connecting the detector to the system bus, always switch the power off.
  1. Open the detector cover (by pushing the cover tab (5). Avoid touching the PIR sensor inside (13) – you could damage it.
  2. Remove the locking screw on the right side of the product (9) Take out the PCB – it is held by a tab (14).
  3. The recommended installation height is 2.5 m above the floor level.
  4. Attach the plastic base to the wall using screws (vertically, with the cover tab facing downwards).
  5. Re-insert the electronics, secure with the tab (14), followed by the screw (9) and connect the bus cable to the terminals (7).
  6. After powering on the control panel, the LED (10) indicates that the detector is not assigned to the system by blinking yellow.
  7. Close the detector cover. To ensure proper compliance with the standards, the top must be secured with the locking screw.
   
Fig.1: Description of extrenal and internal parts of the product
1 – GBS sensor; 2 – LED indicator; 3 – PIR sensor lens; 4 – hole for locking screw; 5 – cover tab; 6 – connector for external tamper contact of the JA-191PL joint bracket; 7 – Bus terminals; 8 – GBS sensor; 9 – GBS module locking screw; 10 – LED status indicators; 11 – production code; 12 – cover tamper sensor; 13 – PIR sensor; 14 – PCB tab;

Assignment to the system and settings

Depending on the type of control panel, use the recommended software or application, see the manual of the control panel.

Technical specifications

Powerfrom the control panel bus, 12 V (8…15 V)
Quiescent current consumption2.4 mA
Maximal current consumption12.8 mA
Recommended installation height2.5 m above the floor
Detection typeAcoustic
PIR detection angle/range90 °/12 m
GBS detection angle/range90 °/9 m
Dimensions64 x 150 x 41 mm
Weight131 g
ClassificationSecurity grade 2/Environmental class II (According to EN 50131-1)
Environmentindoor general
Operating temperature range-10 °C to +40 °C
Average operational humidity75% RH, w/o condensation
Certification bodyTrezor Test s.r.o. (no. 3025)
In compliance withEN 50130-4, EN 55032, EN IEC 63000, EN 50131-1, EN 50131-2-2, EN 50131-2-7-1
Recommended screw2 x ø 3.5 x 40 mm (countersunk head)



JABLOTRON ALARMS a.s. hereby declares that the 1PIRGBS2201OQ is in a compliance with the relevant Union harmonisation legislation: Directives No: 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – Section Downloads.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.