Bus outdoor RFID reader 13,56 MHz
Type: 1READER2304LU
The product is a component of the JABLOTRON system. The reader is designed to scan contactless authorisation elements and it may be used for the activation of a PG output. The reader has a reading part and optical status indication. The device should be installed by a trained technician with a valid certificate issued by an authorised distributor.
Installation
![]() |
When connecting the module to the bus, always switch the power off. |
- Remove the locking screw (6) and open the reader cover.
- Install the plastic base to a chosen place on a wall, so that the tamper contact (5) can be sufficiently compressed when the installation is complete.
- Pull the reader cable through the hole in the plastic base.
- Connect the bus cable into the terminal blocks according to the colours and markings – red terminal +U, yellow A, green B, black GND. For connection outside the armed area, we recommend using the JA-110T isolator.
- Follow the instructions stated in the control panel installation manual. Basic procedure:
- Once powered on, the yellow LED (3) flashes to indicate that the reader is not assigned to the system.
- Open the F-Link software, select an unused position in the Devices tab and click on the Enrol button to enter the Enrolment mode.
- Press the tamper, this action enrols the reader and the yellow LED turns off.
- Close the product cover and secure it with a locking screw (6).
1 – red LED – indicates an armed section; 2 – green LED – indicates a disarmed section; 3 – yellow LED – indicates fault/service/not-assigned to the system; 4 – reading area; 5 – tamper; 6 – locking screw
Setting the properties
To set the properties, use the F-Link program, select the Devices tab. At the product/reader position, click the Enter prompt in the Internal settings column.
The signalization shows the status of a function assigned to the segment. Red LED indicates an armed/turned on PG. Green LED indicates a disarmed section/turned off PG. Yellow LED indicates a fault by permanent light.
Behaviour of optical indication may be set in the F-Link software by selecting from the following options.
The asterisk symbol * signifies the factory default setting.
LED function
None / Indicates section* / Indicates PG / PG indicates inversely
Acoustic indication of selected sections
The asterisk symbol * signifies the factory default setting.
Alarm: *On/Off: Signalizes ongoing alarm in an assigned section.
Entrance delay: *On/Off: Signalizes entry delay in a section to which it is assigned.
Exit delay: *On/Off: Signalizes exit delay in a section to which it is assigned.
Exit delay when partially set: On/*Off
Segment status change: Reader signalized acoustic section in which is assigned.
Mute: On/*Off: If ON is selected, reader will not signalize exit and alarm.
Properties and indication
Indicates permanently – LED 1 or LED 2 lights up permanently/signals the status of the PG/section. The reader displays the status permanently. In case of a power failure, it behaves according to the By status change option.
After valid authorization – applying a card/chip, the signalling is activated and the LED displays the status of the PG/section (selected PG in the Authorization action setting, if selected) for 8 seconds.
After valid authorisation in acc. with EN50131-1 – by reading a card of a user that is defined within the system, the current status of a PG/section is displayed for 4 seconds (selected PG in the Authorization action setting, if selected).
Authorised action
Authorisation triggers an entrance delay: On/Off*: If the section, to which the reader is assigned, is in an armed state, authorisation by the means of reading a card induces an entry delay. Simultaneously it activates a PG.
The reader can be used to control PGs that have the Impulse or Change function set. These functions can be set in the internal settings of the F-link.
Technical specifications
Power | From the control panel bus, 12 V DC (8–15 V) |
---|---|
Quiescent current consumption | 12 mA |
Maximal current consumption | 60 mA |
Type of control device | B |
Operating RFID frequency | 13,56 MHz |
Maximum RFID magnetic field strength | 10,37 dBuA/m (3 m) |
Compatible RFID cards | NFC, Mifare® Classic, Mifare® DESFire® 4, 7 Byte UID |
Dimensions | 46 x 151,5 x 25 mm |
Weight | 185 g |
Cable length | 3,0 m |
Operating temperature range | -25 °C to +60 °C |
Relative humidity | 75% Without condensation |
Environment according to EN 50131-1 | IV. indoor general |
Classification | grade 2 according to EN 50131-1, EN 50131-3 |
Additionally in compliance with | ETSI EN 300 330, EN 50130-4, EN 55032, EN 62368-1, EN IEC 63000 |
Recommended screw | 3 x |
MIFARE® is a registered trademark owned by NXP B.V. There is no affiliation between NXP B.V. and JABLOTRON a.s.
JABLOTRON a.s. hereby declares that the product 1KPAD2318LU is in compliance with the relevant Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – Section Downloads. | ||
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point. |
JA-122E-NFC | MLU530502 (29.08.2024) |
---|