JA-115P


If you want to save to PDF, please select
‘Save as PDF’ when the print dialog opens.

Bus ceiling PIR motion detector

switch to the manual for the JABLOTRON 100+ system

This detector is a BUS device of the JABLOTRON system. It is intended to be used for movement detection in building interiors. The detector should be installed on a ceiling. Its guaranteed detection coverage is 360° with a radius of up to 5.5 metres when installed 3.5 metres above the floor. False alarm immunity is configurable at two levels. The detector has a pulse reaction and it should be installed by a trained technician with a valid certificate issued by an authorized distributor.

Figure 1: Description of external and internal parts of the product
1 – release direction; 2 – fixing direction; 3 – hole for a fixing screw; 4 – indication LEDs; 5 – alignment arrow; 6 – production number; 7 – tamper sensor; 8 – bus connection terminal;

Installation

When connecting the detector to the bus system, always switch the power off.

During the installation pay attention that there should be no obstacles in the detector’s view, such as:

  • items that change temperature quickly (electric stove, gas appliances)
  • objects that move (e.g. waving curtains over the heating, robotic vacuum cleaner)
  • no obstacles obstructing the view of the protected area
  • moving pets

We do not recommend installing the detector:

  • against windows or spotlights
  • in places where air flows (ventilation, air conditioning, vents, leaky doors etc.)
  1. Turn the top part counter-clockwise (1) to open the detector.
  2. Insert the BUS cable through an appropriate cut-out hole in the base and attach the detector base to a selected place on a ceiling.
  3. Eject the removable part of the bus terminal (8) from the base and connect to it the BUS wires according to the colour label and description.
  4. When switched on, the red LEDs will light up and stay on until the end of detector stabilization (up to 1 minute). After that a yellow LED will flash (to indicate the detector has not been enrolled into the system).
  5. Then follow the installation manual of the control panel.
  6. Attach the detector back onto its base and fasten it by turning it clockwise (2). The detector can only be attached at one position marked by alignment arrows and the JABLOTRON logo (5) on both parts.
  7. To comply with norms and their requirements, it is necessary to attach the top part to the base (3) using a fixing screw included in the packaging.

Asignment to the system

Depending on the type of control panel, use the recommended software or application, see the control panel manual.

Technical parametres

Powerfrom the control panel BUS 12 V DC (9…15 V)
Quiescent current consumption2,8 mA
Maximal current consumption30 mA
Recommended installation height2,5–3,5 m above the floor
Detection angle/detection coverage360 °/11 m (mounting high – 3.5 m)
DimensionsØ 125 x 40 mm
Weight120 g
ClassificationGrade 2 according EN 50131-1
Operational environmentEnvironmental class II indoor general
Operational temperature range-10 °C to +40 °C
Average operational humidity75% RH, non-condensing
Certification bodyTrezor Test s.r.o. (n. 3025), KIWA Nederland B.V.
Complies withEN 50131-1, EN 50131-2-2, EN 50130-4, EN 55032, EN IEC 63000, T 031
Recommended screw2 x ø 3.5 x 40 mm (countersunk head)



JABLOTRON ALARMS a.s. hereby declares that the JA-115P is in compliance with the relevant European Union harmonisation legislation: Directives No:, 2014/30/EU, 2011/65/EU, when used as intended. The original of the conformity assessment can be found at www.jablotron.com – the Downloads section.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.

JA-115PMOM54603
(04.10.2024)