JA-112M


If you want to save to PDF, please select
‘Save as PDF’ when the print dialog opens.

BUS module for magnetic contact – 2 inputs

switch to the manual for the JABLOTRON 100+ system

The JA-112M is a BUS device of the JABLOTRON system. It has two wire inputs that can be connected unbalanced, single or double balanced. It is primarily used to connect magnetic contact (e.g. SA-201, SA-203, SA-211). The module has a status reaction (reports its activation and deactivation) and takes two positions in the system. It should be installed by a trained technician with a valid certificate issued by an authorized distributor.

Installation

Always connect the bus when the system is completely powered off.

When selecting the right location for the module, bear in mind that the wires leading to the detectors should not be longer than 100 m.

  1. Open the module cover by pressing the cover tab (1).
  2. Take out the PCB from the plastic base by pressing the tab on the left part (3).
  3. Push the cables through the plastic base and attach it to the selected place with screws. For a more comfortable installation there are cut-out holes (4) in the plastic and also a cable lead with fixing clips under the module board (5).
  4. Insert the PCB back and connect the cables to the terminals (9, 10).
  5. If you want to use a balanced loop for better protection of a magnetic contact connection use a 1 kΩ resistor in series with the detector (see the picture 2). The balance function must be enabled in the module settings.
  6. Proceed by following the control panel installation manual.
  7. Close the module cover and test the module’s function.
Pic. 1: Description of internal and external parts of the product.
1 – cover latches; 2 – LED indicator; 3 – PCB tab; 4 – cut-out holes; 5 – fixing clips for cables coming from the top cut-out holes; 6 – red and yellow LED indicator; 7 – production code; 8 – tamper sensor; 9 – magnetic contact terminal; 10 – BUS terminal

Pic. 2: Loop balancing

Assigment to the system

Depending on the type of control panel, use the recommended software or application, see the manual of the control panel.

Technical specifications

Powerfrom control panel BUS 12 V (9–15 V)
Quiescent consumption in standby mode7 mA
Maximum current consumption12 mA
Maximum length of cable to the magnetic contact100 m
Dimensions, Weight110 x 44 x 26 mm, 51 g
Classificationgrade 2/envinronment class II (according to EN 50131-1)
Envinronmentindoor general
Operational temperature range-10 °C to +40 °C
Average operational humidity75% RH, non-condensing
Certification bodyTrezor Test s.r.o. (no. 3025), Telefication B.V.
Also complies withEN 50131-1, EN 50131-3, EN 50130-4, EN 55032, EN IEC 63000, T 031
Recomnended screw2 x ø 3,5 x 40 mm (flat had screw)



JABLOTRON ALARMS a.s. hereby declares that the JA-112M is in compliance with the relevant European Union harmonisation legislation: 2014/30/EU, 2011/65/EU, when used as intended. The original of the conformity assessment can be found at www.jablotron.com – the Downloads section.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.

JA-112MMLM58606
(10.06.2024)