Bus temperature detector
The JA-111TH is a component of the JABLOTRON system. It serves for temperature measurement and forwarding measured data to MyJABLOTRON. MyJABLOTRON manages and stores measured data for further use, for instance activating a selected PG output, the SMS reporting of exceeding temperature limits or to create graphs of measured temperatures. All functions are programmable directly in MyJABLOTRON. This product should be installed by a trained technician with a valid certificate issued by an authorised distributor.
Select the installation place according to the temperature measuring requirements. It is not recommended to install the detector near heat sources affecting measuring (heaters, electric fans, air conditioning outlets, fireplace inserts, etc.). The detector can also be installed in an outdoor environment but it has to be placed into a suitable box with a minimum of IP65 housing, the JA-192PL-A for example.
Installation
When connecting the detector to the system bus, always switch the power off. |
- Open the detector cover by pushing the tab (1). Punch though the holes for the bus cable in the plastic base.
- Insert the bus cable and attach the plastic base to the required place using screws.
- Connect the bus cables to the terminals (6).
- When the device is switched on, the yellow LED (5) starts flashing repeatedly to indicate that the module has not been enrolled to the system.
- Proceed according to the control panel installation manual and than close the detector cover.
1 – cover tab; 2 – LED indication; 3 – Jablotron system bus; 4 – red LED indicator; 5 – yellow LED indicator; 6 – bus terminals; 7 – production code; 8 – LEARN (enrollment) button; 9 – measurement sensor;
Assignment to the system and settings
Depending on the type of control panel, use the recommended software or application, see the manual of the control panel.
Technical specifications
Power | from the control panel bus 12 V DC (9…15 V) |
---|---|
Quiescent current consumption | 3.3 mA |
Maximal current consumption | 5 mA |
Dimensions | 55 x 27 x 16 mm |
Weight | 12 g |
Temperature measurement range | -20 °C to +70 °C |
Operational temperature range | -20 °C to +70 °C |
Average operating humidity | 75% RH, non-condensation |
Temperature measurement range accuracy | ±0.5 °C |
Also complies with | EN 50130-4, EN 55032 |
Recommended screw | 2 x ø 3.5 x 40 mm (countersunk head) |
JABLOTRON a.s. hereby declares that the JA-111TH is in compliance with the relevant European Union harmonisation legislation: Directives No: 2014/30/EU, 2011/65/EU, when used as intended. The original of the conformity assessment can be found at www.jablotron.com – the Downloads section. | ||
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point. |
JA-111TH | MNG55109 (15.11.2024) |
---|