The JA-111H-AD TRB is a component of the JABLOTRON system. It serves to control the system from an external device with a status or impulse output and it can also provide power from the control panel bus. The module should be installed by a trained technician with a valid certificate issued by an authorised distributor.

Installation

When connecting the module to the system bus, always switch the power off.

The power consumption of the connected detector must not exceed 50 mA (the module power supply output is not protected against overloading).

It is designed to be installed inside a standard wired detector (with contact outputs) but thanks to the extended wires can also be installed out of it in a protected installation box.

  1. Install the module at a suitable place in the controlling device (such as finger print reader) or inside a protected installation box. The wires can be extended to up to 3 m maximum. When the module is installed inside the controlling device ensure that it cannot make a short circuit because of poor isolation.
  2. Connect the wires of the module according to figure 1.
  3. Connect the bus cable and switch on the control panel power.
  4. The control panel has to be in service mode.
  5. Close the cover of the controlling device with the installed module inside.
Figure 1: Description of the internal parts of the product and connecting the wires of the module
1 – bus terminals; 2 – production code; 3 – yellow LED indicates fault/not enroled device, the red LED indicates by flashing activation of any input; 4 – wires of the module, see the following Table 1;
WireMeaningFunction
Red+12 VPower for connected device
BlackGNDCommon wire
WhiteINPControl input
BlueTMPTamper input
YellowTRBTrouble input/Unset
Table 1: Wires of the module

Enrolment to the system and settings

According to the type of control panel use recommended software or application – see control panel manual.

Technical specifications

Powerfrom control panel bus 12 V DC (9…15 V)
Nominal current consumption8 mA (+ consumption of connected devices) all inputs connected to GND
Maximal current consumption12 mA (+ consumption of connected devices)
Maximum allowed current of the connected detector50 mA
Dimensions16 x 30 x 12 mm
Weight8 g
ClassificationSecurity grade 2/environmental class II
According toEN 50131-1, EN 50131-3 (ACE type B)
Note: valid only, if it is built-in to security grade 2 or higher certified housing
EnvironmentalIndoor general
Operating temperature range-10 °C to +40 °C
Average humidity75% RH non-condensing
Certification bodyTrezor Test s.r.o. (no. 3025)
Valid for installation of the module into a product certified for security grade 2/environmental class II and also if the connection to the module is compatible.
Also complies withEN 50130-4, EN 55032, EN IEC 63000



JABLOTRON a.s. hereby declares that the product JA-111H-AD TRB is in a compliance with the relevant Union harmonisation legislation: Directives No: 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – Section Downloads.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.