Bus acoustic glassbreak detector

The JA-110B is component of the JABLOTRON system. It is used to detect the breaking of glass windowpanes and glass surfaces in buildings. It reacts to the change of air pressure accompanied by the characteristic sound of breaking glass. The detector has a pulse reaction (only reports its triggering). The detector should be installed by a trained technician with a valid certificate issued by an authorized distributor.

Installation

When connecting the module to the system bus, always switch the power off.
  1. Open the detector cover by pushing the latch (1) with the flat screwdriver.
  2. Take out the PCB – it is held with a latch (5).
  3. Insert the bus cable and screw the rear cover part to the wall.
  4. Insert PCB back and connect bus cables to the bus terminals (6).
  5. Set up the sensitivity of acoustic sensor with the trimmer (10).
  6. Close the detector cover.
Figure 1: Description of external and internal parts of the product
1 – cover latch; 2 – hole for acoustic sensor; 3 – light guide; 4 – acoustic sensor; 5 – PCB latch; 6 – bus terminals; 7 – serial number; 8 – red LED activation indicator; 9 – yellow LED fault indicator; 10 – trimmer for sensitivity set up; 11 – tamper contact;

Enrolment to the system

Depending on the type of control panel, use the recommended software or application, see the manual of the control panel.

Technical specifications

Powerfrom the control panel bus 12 V (9…15 V)
Quiescent current consumption5 mA
Maximal current consumption5 mA
Recommended installation height2.5 m above the floor
Detection distanceup to 9 m
Minimum windowpane size0.6 x 0.6 m
Stabilization time after the switching onmax. 60 s
Dimensions40 x 100 x 22 mm
Weight50 g
ClassificationSecurity Grade II / Environmental class II (according to EN 50131-1)
Environmentindoor general
Operating temperature range-10 °C to +40 °C
Average operational humidity75% RH non-condensation
Certification bodyTrezor Test s.r.o. (no. 3025), Kiwa Nedeland b. v.
In complience withEN 50131-1, -2-7-1, T 031, EN 50130-4, EN 55032, EN IEC 63000
Recommended screw2 x ø 3.5 x 40 mm (countersunk head)



JABLOTRON a.s. hereby declares that the JA-110B is in compliance with the relevant European Union harmonisation legislation: Directives No: 2014/30/EU, 2011/65/EU, when used as intended. The original of the conformity assessment can be found at www.jablotron.com – the Downloads section.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.

JA-110BMLX53109