JA-110A II


If you want to save to PDF, please select
‘Save as PDF’ when the print dialog opens.

Bus internal siren with battery back-up

switch to the manual for the JABLOTRON 100+ system

The JA-110A II siren is a component of the JABLOTRON system. It is used for alarm indication inside a indoor premises. Pressing a button on the siren can silence the alarm indication in progress (which can also confirm somebody’s presence on the premises or trigger a panic alarm (optional function). The siren takes one position in the system and should be installed by a trained technician with a valid certificate issued by an authorized distributor.

Obrázek 1
Pic 1: disassembly of the siren before installation
Obrázek 2
Pic 2: Description of intern parts of product:
1 – LED indicators; 2 – buttons; 3 – production number; 4 – button tabs; 5 – piezo-electric siren; 6 – bus terminal; 7 – tamper sensors; 8 – battery connector for BAT-3V2-CR2

Installation

  1. Remove the body (buttons) of the siren from the plastic frame by pressing on a side of the body (1.) using a screwdriver as shown in figure 1.
  2. Remove the middle part of the frame (3.) by pushing the 4 tabs indicated by arrows (2.)
  3. Push the BUS cable through a designated rectangular recess in the plastic base.
  4. Attach the plastic base to the selected place using screws. If the siren uses a battery, place it underneath the top side of the plastic base as shown in figure 1.
  5. Assemble the plastic frame with the plastic base which will fix the battery in position.

Assignment to the system and settings

According to the type of control panel use recommended software or application – see control panel manual.

Specifications

Powerfrom the control panel bus 12 V DC (8…15 V)
Optional back up battery3.2 V LiFePo4 CR2 0.4 Ah
Please note: battery is not included
Quiescent current consumption for backup5 mA
Maximum current consumption for cable selection120 mA
LowBatt state2.9 V
Type of warning devicetype Z/24hr back-up
Sirenpiezo-electric, 100 dB/m (±5 dB/m)
Dimensions80 x 80 x 35 mm
Weight92 g
ClassificationSecurity grade 2/Environmental class II (EN 50131-1)
Operational environmentIndoor general
Operating temperature range-10 °C to +40 °C
Average operating humidity75% RH, without condensation
Certification bodyTrezor Test s.r.o. (no. 3025)
Complies withEN 50131-1, EN 50131-4, EN 50130-4, EN 55032, EN 62368-1, EN 50581
Recommended screw2 x ø 3.5 x 40 mm (countersunk head)



JABLOTRON a.s. hereby declares that the JA-110A II is in a compliance with the relevant European Union harmonisation legislation: Directives No: 2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com – The Downloads Section.
Note: Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste handling. Please return the product to the dealer or contact your local authority for further details of your nearest designated collection point.

JA-110A IIMLP22003
(9.5.2024)